 Technical problems
Q: Refrigerant low pressure becoming too high
A: Failure cause: Expansion valve is broken
Solving method: Change expansion valve

Failure cause: Refrigeration system heat levelis too low
Solving method: Increasing the heat

Failure cause: Hrat valve opens too much
Solving method: Decreasing heat valve opening

Failure cause: Expansion valve heat load is too big 
Solving method: Decreasing inlet temperature and inlet air
capacity,Increasing inlet pressure

Failure cause: Refrigerant high pressure becoming too high
Solving method: Decreasing refrigerant high pressure
Q: Refrigerant low pressure becoming too low
A: Failure cause: Refrigerant is not enough
Solving method: Add refrigerant

Failure cause: Refrigeration system load is too small
Solving method: Increasing heat load of refrigerant system

Failure cause: Heat valve opens not enough
Solving method: Adjust heat valve

Failure cause: Refrigerant high pressure becoming too low
Solving method: Increasing refrigerant high pressure
Q: Refrigerant high pressure becoming too high
A: Failure cause: Environment temperature is too high(Air-cooled)
Solving method: Increasing environment aeration or decreasing environment temperature

Failure cause: Refrigerrant high pressure switch setting is  incorrect
Solving method: Adjust the setting
Q: Outlet air pressure drop is too big
A: Failure cause: Air volume capacity exceeds the stangard rating
Solving method: Choose a air dryer which fits the capacity

Failure cause: Inlet valve are not fully opened 
Solving method: Open all valves

Failure cause: Air filter clogging
Solving method: Wash change air filter element

Failure cause: Evaporator pipe frosta and clogs
Solving method: Solving as refrigerant low pressure becoming too low

Failure cause: Air pressure becoming too low
Solving method: Increasing system pressure

Failure cause: Air temperature becoming too high
Solving method: Decreasing inlet air temperature
Q: Product downtime
A: Failure cause:In Refrigeration system,device for drying and filtering is clogging.
Solving method:solvingas refrigerant high pressure beuming too low.
Q: Poor dehumidification
A: Failure cause: Auto drains clogging and damaged.
Solving method: Wash and change auto drains.
 